@@ -27,14 +27,14 @@ Results
.. figure:: ../../tests/models_basic/hertzian_dipole_fs_analytical/hertzian_dipole_fs_analytical.png
:width: 600 px
Time history of the electric and magnetic field components of the modelled and analytical solutions.
Time history of the electric and magnetic field components of the modelled and analytical solutions ('Ref', in this case, indicates solution calculated from theory).
.. _hertzian_dipole_fs_results_diffs:
.. figure:: ../../tests/models_basic/hertzian_dipole_fs_analytical/hertzian_dipole_fs_analytical_diffs.png
:width: 600 px
Percentage differences between the modelled and analytical solutions ('Ref', in this case, indicates solution calculated from theory)
Percentage differences between the modelled and analytical solutions.
The match between the analytical and numerically modelled solutions is excellent. The maximum difference is approximately 1%, which is observed in the Ez field component (the same direction as the Hertzian dipole source). The other electric field components exhibit maximum differences of approximately 0.5%, and the magnetic field components 0.25%.