From f88087fd43a94fed7779e1f7e843caeb8fa78655 Mon Sep 17 00:00:00 2001 From: Craig Warren Date: Thu, 26 Jan 2017 17:19:40 +0000 Subject: [PATCH] Updated comments on legend. --- docs/source/comparisons_analytical.rst | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/docs/source/comparisons_analytical.rst b/docs/source/comparisons_analytical.rst index 1703c23f..21caede3 100644 --- a/docs/source/comparisons_analytical.rst +++ b/docs/source/comparisons_analytical.rst @@ -27,14 +27,14 @@ Results .. figure:: ../../tests/models_basic/hertzian_dipole_fs_analytical/hertzian_dipole_fs_analytical.png :width: 600 px - Time history of the electric and magnetic field components of the modelled and analytical solutions. + Time history of the electric and magnetic field components of the modelled and analytical solutions ('Ref', in this case, indicates solution calculated from theory). .. _hertzian_dipole_fs_results_diffs: .. figure:: ../../tests/models_basic/hertzian_dipole_fs_analytical/hertzian_dipole_fs_analytical_diffs.png :width: 600 px - Percentage differences between the modelled and analytical solutions ('Ref', in this case, indicates solution calculated from theory) + Percentage differences between the modelled and analytical solutions. The match between the analytical and numerically modelled solutions is excellent. The maximum difference is approximately 1%, which is observed in the Ez field component (the same direction as the Hertzian dipole source). The other electric field components exhibit maximum differences of approximately 0.5%, and the magnetic field components 0.25%.